泰仕AFLEX-3005撓性交流電力及諧波分析鉤表_AFLEX3005鉗形電流表
電器規格: (23℃±5℃)
有效功率?(AC Watt):
范圍
(5~3000A)
|
分辨率
|
讀值誤差
|
|
> 20 V?和?>?30A
|
< 20V?或?<?30A
|
||
10.0 – 999.9 W
|
0.1W
|
±1% of range
|
±2% of range
|
1.000 – 9.999 KW
|
0.001 KW
|
±1% of range
|
±2% of range
|
10.00 – 99.99 KW
|
0.01 KW
|
±1% of range
|
±2% of range
|
100.0 – 999.9 KW
|
0.1 KW
|
±1% of range
|
±2% of range
|
1000 – 9999 KW
|
1 KW
|
±1% of range
|
±2% of range
|
?視在功率?(AC Apparent Power, VA):
范圍
(5~3000A)
|
分辨率
|
讀值誤差
|
|
> 20 V?和?>?30A
|
< 20V?或?<?30A
|
||
10.0 – 999.9 VA
|
0.1VA
|
±1% of range
|
±2% of range
|
1.000 – 9.999 KVA
|
0.001 KVA
|
±1% of range
|
±2% of range
|
10.00 – 99.99 KVA
|
0.01 KVA
|
±1% of range
|
±2% of range
|
100.0 – 999.9 KVA
|
0.1 KVA
|
±1% of range
|
±2% of range
|
1000 – 9999 KVA
|
1 KVA
|
±1% of range
|
±2% of range
|
?無效功率?(AC Reactive Power, VAR):
范圍
(5~3000A)
|
分辨率
|
讀值誤差
|
|
> 20 V?和?>?30A
|
< 20V?或?<?30A
|
||
10.0 – 999.9 VAR
|
0.1VAR
|
±1% of range
|
±2% of range
|
1.000 – 9.999 KVAR
|
0.001 KVAR
|
±1% of range
|
±2% of range
|
10.00 – 99.99 KVAR
|
0.01 KVAR
|
±1% of range
|
±2% of range
|
100.0 – 999.9 KVAR
|
0.1 KVAR
|
±1% of range
|
±2% of range
|
1000 – 9999 KVAR
|
1 KVAR
|
±1% of range
|
±2% of range
|
?功率因素?(PF)
范圍 | 分辨率 | 誤差 | |
> 20 V?和?>?30A
|
< 20V?或?<?30A
|
||
0.000 – 1.000 | 0.001 | ± 0.04 | ±0.1 |
?交流電流
范圍
|
分辨率
|
讀值誤差
|
5.0 –?300.0A
|
0.1A
|
±1% of range
|
300.0 –?999.9A
|
0.1A
|
±1% of range
|
1000 –?3000 A
|
1 A
|
±1% of range
|
?交流電壓?(過載保護AC 800V)
范圍
|
分辨率
|
讀值誤差
|
4.0 V – 600.0 V
|
0.1 V
|
±0.5% ± 5dgts
|
?交流電壓諧波百分比
范圍
|
分辨率
|
誤差
|
1 – 20th
|
0.1%
|
±2%
|
21 – 50th
|
0.1%
|
4% of reading ± 20dgts
|
?交流電壓諧波強度
范圍
|
分辨率
|
誤差
|
1 – 20th
|
0.1V
|
±2% ± 0.5V
|
21 – 50th
|
0.1V
|
4% of reading ±0.5V
|
?交流電流諧波百分比
范圍
|
分辨率
|
誤差
|
1 – 20th
|
0.1%
|
±2%
|
21 – 50th
|
0.1%
|
4% of reading ± 20dgts
|
?交流電流諧波強度?(電流真均方根值<300A時,能有正確的1~50次電流諧波強度量測)
范圍?(5-300A)
|
分辨率
|
誤差
|
1 – 20th
|
0.1A
|
±2% of range ±0.4A
|
21 – 50th
|
0.1A
|
±4% of range ±0.4A
|
?交流電流諧波強度?(AC3000A>真均方根值>300A時,能有正確的1~50次電流
? ? ? ? ? ? 諧波強度量測)
范圍
|
分辨率
|
誤差
|
1 – 20th
|
0.1A
|
±2% of range ±40A
|
21 – 50th
|
0.1A
|
±4% of range ±40A
|
?相位角?(Φ, V > 20V, A >?30A)
范圍 | 分辨率 | 誤差 |
-180° to 180° | 0.1° | ± 1° |
0° to 360° | 0.1° | ± 1° |
?總諧波失真?(THD-F)
范圍
|
分辨率
|
誤差
|
0.0 – 20%
|
0.1%
|
± 2%
|
20 – 100%
|
0.1%
|
± 6% of reading ± 1%
|
100 – 999.9 %
|
0.1%
|
± 10% of reading ± 1%
|
?交流電壓峰值?(均方根值>10V)?或?交流電流峰值?(均方根值>30A)
范圍
|
取樣時間
|
讀值誤差
|
50 Hz
|
39 μs
|
± 5% ± 30 digits
|
60 Hz
|
33 μs
|
± 5% ± 30 digits
|
?交流電壓波形因素?(C.F.)?(均方根值> 10V)?或?交流電流波形因素?(均方根值>?30A)
范圍
|
分辨率
|
讀值誤差
|
1.00 – 99.99
|
0.01
|
± 5% ± 30 digits
|
?交流電壓頻率?(均方根值?> 10V)?或?交流電流頻率?(均方根值?>?30A?)
范圍
|
分辨率
|
誤差
|
46 – 65
|
0.1
|
± 0.2Hz
|
一般規格:
撓性線長度:
|
610mm?(24”)
|
最小彎曲直徑:
|
35mm
|
探測環連接頭直徑:
|
23mm
|
連接頭纜線直徑:?????
|
14mm
|
撓性纜線線長:
|
1700mm
|
輸出纜線線長:
|
1700mm
|
儀器尺寸:
|
130mm(長) x?80mm(寬)x?43mm(高)
5.1”(長) x?3.1”(寬) x?1.7”(高)
|
電池:
|
3號AA 1.5V x 2
|
電池壽命:
|
200小時?(@ 2000mAH.)
|
顯示:
|
4+4?位LCD顯示
|
范圍?(檔位)?選擇:
|
自動
|
過載警示:
|
OL
|
消耗電流:
|
約10mA
|
低電池顯示:
|
![]() |
自動關機:
|
30分鐘
|
LCD更新時間:
|
每秒2次
|
取樣率:
|
512 (電壓或電流); 256 (瓦特)
|
內存容量:
|
8000?筆記錄
|
取樣時間:
|
0~600?秒
|
數據記錄期間:????????
|
8000 x?取樣時間?(0~600秒)
|
工作溫度:
|
5°C ~ 50°C
|
工作濕度:
|
15% ~ 85%相對濕度
|
量測高度:
|
最高至2000M
|
儲存溫度:
|
-20°C ~ 60°C
|
儲存濕度:
|
15% ~ 85%相對濕度
|
重量:
|
430g (含電池)
|
附件:
|
測試棒
說明書?x 1
1.5V電池?x 2
攜帶箱?x 1
軟件光盤?x 1
軟件說明書?x 1
|
分類和標簽: